Negative Pressure Ventilation · Energy Recovery
Everyday energy recovery ventilation.
Negative pressure when needed.
For hospitals, care facilities and homes
Energy recovery ventilation with negative pressure control
Manage everyday ventilation and negative pressure operation
with one integrated unit.
01 / OPERATING MODES
| Auto | Automatically adjusts supply and exhaust airflow according to indoor CO₂ levels. |
|---|---|
| Negative pressure | Operates according to the differential pressure setpoint to help reduce air leakage from the designated space into surrounding areas. |
| Supply | Supplies outdoor air indoors. Select low, medium or high airflow. |
| Exhaust | Discharges indoor air outdoors. Select low, medium or high airflow. |
02 / CONTROL & MAINTENANCE
Example screens for automatic ventilation and negative pressure operation. The interface may vary with the supplied configuration.
Wall-mounted controller
Check the operating mode, temperature, humidity and CO₂ status, and view the current differential pressure during negative pressure operation.
H13 HEPA filtration
Combined filters in the main unit and a separate HEPA filter box for negative pressure operation provide fine-particle filtration.
Filter replacement and clogging alerts
Alerts based on filter operating time and clogging status help you plan inspection and replacement.
Heat exchanger: recommended replacement every 3 years
Inspect and replace filters according to operating conditions, contamination, alerts and the product manual.
03 / KEY SPECIFICATIONS
Model selection is based on the required airflow and available installation space.
| Item | 150 CMH WS-NHE-04 |
500 CMH WS-NHE-03 |
|---|---|---|
| Rated airflow | 150 m³/h | 500 m³/h |
| Power consumption | 88 W | 212 W |
| Dimensions W × D × H |
920 × 700 × 244 mm |
1,040 × 800 × 381 mm |
| Weight | 27.5 kg | 49 kg |
| Power supply | Single-phase 220 V / 60 Hz | |
| Total heat exchange efficiency Cooling / Heating |
≥45% / ≥70% | |
| Negative pressure filter | H13 HEPA filter | |
Power consumption, weight and efficiency are based on the corresponding product labels. Heat exchange efficiency describes energy recovery performance, not electricity bill savings.
The alternative 150 CMH model, WS-NHE-01, has different dimensions: 918 × 807 × 250 mm. Confirm the model and installation dimensions when ordering.
04 / INSTALLATION
Actual Ansim Homecare installation
Applications
Hospitals, care facilities, apartments and houses requiring ventilation and negative pressure operation in a designated space
Optional configurations
Central control system · External differential pressure display · Pass chamber
Actual airflow and negative pressure performance depend on room airtightness, duct resistance, filter configuration and whether doors are open. Site-specific design and performance verification after installation are required.
Tell us the site location, floor area, ceiling height and intended use,
along with existing ventilation equipment and your preferred schedule.
We will advise on a suitable model and installation configuration.
WOSEM CO., LTD. · Made in the Republic of Korea